Emerson MVME147 Computer Hardware User Manual


 
TARGET Enable Custom Packet
2-19
2
Note
A linked command with the flag bit set is not supported,
and the flag bit is ignored if it is set.
TARGET Enable Custom Packet
The TARGET enable custom packet is shown in the following table.
Even Byte \
Odd Byte \
FC B8 74 30
+$00 Controller LUN Device LUN
+$02 Status Byte 0 Status Byte 1 (Note 1)
+$04 Not Used
+$06 Not Used
+$08 Command Table Pointer (MSW) (Note 2)
+$0A Command Table Pointer (LSW) (Note 2)
+$0C 0000
+$0E Flag = C 0 0 0
+$10 0000
+$12 0000
+$14 0 0 Function Code (1C)
+$16 Interrupt Level Vector Number
+$18 Status Byte 2 Status Byte 3 (Note 1)
+$1A 0 0 Retry Count
$00 00000xxx Controller logical unit
number
$01 00000xxx Device logical unit
number
$02 xxxxxxxx Status from SCSI
firmware (byte 0)
(Note 1)