TARGET Sequence Custom Packet
2-23
2
+$1A 0 0 Retry Count
$00 00000xxx Controller logical unit
number
$01 00000xxx Device logical unit
number
$02 xxxxxxxx Status from SCSI
firmware (byte 0)
(Note 1)
$03 xxxxxxxx Status from SCSI
firmware (byte 1)
(Note 1)
$04 xxxxxxxx xxxxxxxx Script pointer (MSW)
$06 xxxxxxxx xxxxxxxx Script pointer (LSW)
$08 xxxxxxxx xxxxxxxx Command table
pointer (MSW) (Note
2)
$0A xxxxxxxx xxxxxxxx Command table
pointer (LSW) (Note
2)
$0C 00000000 00000000 Reserved
$0E 1....... TARGET role
.0...... TARGET sequence
..000000 Reserved
$0F 00000000 Reserved
$10 00000000 00000000 Reserved
$12 00000000 00000000 Reserved
$14 00000000 Reserved
$15 xxxxxxxx SCSI function ($1C =
custom SCSI
sequence)
$16 00000xxx Interrupt level (7 to 1)
$17 xxxxxxxx Vector number to use
upon return
$18 xxxxxxxx Status from SCSI
firmware (byte 2)