Installing Module into Matrix E7 or Matrix N7 Chassis
3-6 Installation
Example 6 (Figure 3-1, F)
ThemodulearrangementinthisexampleissimilartotheoneshowninFigure 3‐1,E and
describedinExample5.TheonlydifferenceisthataDFE‐Diamondbridgingmoduleisinstalled
inslot2,enablingallmodulestocommunicatewitheachother.
Rule:Inthisexample,the7H4382‐49
DFE‐DiamondbridgingmoduleservesasboththeFTM1‐to‐
FTM2bridgeandthefive‐to‐sevenslotproxybridge.The6x3xxdoesnotserveasaproxybridge
inthisconfigurationbecausethe7H4382‐49isinaslotwithalowernumber.
Installing Module into Matrix E7 or Matrix N7 Chassis
ToinstallmoduleintotheMatrix E7 chassis,referto“BackplaneConnectionsandInstallation
Rules”(page 3‐3)tofamiliarizeyourselfwiththeFTM1andFTM2backplaneconnectionsandthe
modulehardwareinstallationrules. Thenproceedto“Preparation”(page 3‐6)tostartthe
installationprocess.
ToinstallaDFE‐DiamondmoduleintoaMatrix N7
chassis,proceeddirectlyto“Preparation”
(page 3‐6)tostarttheinstallationprocess.
Preparation
1. Removetheblankpanelcoveringtheslotinwhichthemodulewillbeinstalled.Allotherslots
mustremaincoveredtoensureproperairflowforcooling.(Savetheblankplateintheevent
youneedtoremovethemodule.)
2. Removethemodulefromtheshippingbox.(Savetheboxandpacking
materialsintheevent
themoduleneedstobereshipped.)
3. Locatetheantistaticwriststrapshippedwiththechassis.Attachtheantistatic wriststrapto
yourwristandplugthecablefromtheantistaticwriststrapintotheESDgroundingreceptacle
attheupperrightcornerofthechassis.
4. Removethemodule
fromtheplasticbag.(Savethebagintheeventthemodulemustbe
reshipped.)ObserveallprecautionstopreventdamagefromElectrostaticDischarge(ESD).
5. Examinethemodulefordamage.Ifanydamageexists,DONOTinstallthemodule.
ImmediatelycontactEnterasysNetworks.Referto“GettingHelp”onpagexiv.
Caution: Failure to observe static safety precautions could cause damage to the module. Follow
static safety handling rules and wear the antistatic wrist strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the board or
components can cause damage.
Precaución: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad para la
manipulación del producto y no olvide utilizar la pulsera antiestática.
No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto cortante
entra en contacto con la placa o con los componentes, éstos podrían dañarse.