Completing the Installation
3-18 Installation
Figure 3-8 Matrix DFE Startup Screen Example (N7 Chassis)
Completing Installation of DFE-Diamond Module in an Existing System
InanestablishedDFEDiamondmodulesystem,
•aDFEDiamondmoduleisalreadyestablishedasthemanagementmodule,
•thepasswordshavealreadybeensetforvarioususers,
•thesystemIPaddressisset,and
•othersystemparametershavebeenset.
WhenyouinstallanewDFEDiamondmoduleintoasystemwithan
existingconfigureduser
account,thecurrentsystemsettingsinthataccountarealreadyrecognizedbythenew
DFEDiamondmoduleanditwilloperateaccordingly.
Ifyouneedtochangeanysettings,youcanconnectaterminaltothelocalconsoleportas
describedinConnectingtoCOMPortfor
LocalManagementonpage 3 11toaccesssystem
management,oruseaTelnetconnectiontoaccesstheDFEDiamondmodulesystemmanagement
asdescribedinChapter3oftheEnterasysMatrixDFEDiamond/PlatinumSeriesConfigurationGuide.
Logging in with an Administratively-Configured User Account
Ifthedevice’sdefaultuseraccountsettingshavebeenchanged,proceedasfollows:
1. Attheloginprompt,enteryouradministrativelyassignedusername,pressENTER.
2. AtthePasswordprompt,enteryourpassword,pressENTER.
ThenoticeofauthorizationandtheMatrixpromptdisplaysasshownbackinFigure 3 8 .
login: admin
Password:
M A T R I X N7
Command Line Interface
Enterasys Networks, Inc.
50 Minuteman Rd.
Andover, MA 01810-1008 U.S.A.
Phone: +1 978 684 1000
E-mail: support@enterasys.com
WWW: http://www.enterasys.com
(c) Copyright Enterasys Networks, Inc. 2003
Chassis Serial Number: xxxxxxxxxxxx
Chassis Firmware Revision: xx.xx.xx
Matrix N7(su)->
Note: Users with Read-Write (rw) and Read-Only access can use the set password
command to change their own passwords. Administrators with Super User (su) access
can use the set system login command to create and change user accounts, and the set
password command to change any local account password. For information on the set
password and set system login commands, refer to Chapter 3 in the
Enterasys Matrix DFE-
Diamond/Platinum Series Configuration Guide
.