Enterasys Networks 7KR4297-02 Switch User Manual


 
Overview of DFE-Diamond Module Shutdown Procedure
Matrix DFE-Platinum Series Module Installation Guide 4-5
Overview of DFE-Diamond Module Shutdown Procedure
TheDFEDiamondmodulesinstalledinaMatrixE7,MatrixN3,orMatrixN7chassisare
interdependentandoperateunderasingleIPaddressasasingle,distributedswitchsystem
(hardware,databases,andpersistentstorage).Inthisoperatingenvironment,theDFEDiamond
modulemustshutdowninanorderlyfashionto
ensurethattheothermodulesinthesystemand
otherdevicesonthenetworkarenotifiedoftheimpendingchange.Thedevice(s)canthenmake
intelligentdecisionsandstabilizethenetworkbeforethechangeismade;therebyincreasing
networkavailability.
YoucanshutdownaDFEDiamondmoduleinanoperating
systemusingtheOFFLINE/RESET
switchshowninFigure 42.Therearetwoshutdownprocedures.
Recommendedshutdownprocedure(“RecommendedShutdownProcedureUsingOFFLINE/
RESETSwitchonpage 46)
Lastresortshutdownprocedure
(notrecommended) (“LastResortShutdownProcedure
UsingOFFLINE/RESETSwitchonpage 47)
User parameters (IP
address, device and
module name, etc.)
were lost when the
module power was
cycled, the front
panel OFFLINE/
RESET switch was
pressed.
Position of Mode switch (7),
Persistent Data Reset, was
changed sometime before
either cycling power or
pressing the OFFLINE/
RESET switch, causing the
user-entered parameters to
reset to factory default
settings.
Clear Persistent Data that
was set through Local
Management.
The module was moved
either from slot-to-slot or
from chassis-to-chassis.
Reenter the lost parameters as necessary. Refer to
the Enterasys Matrix DFE-Diamond/Platinum Series
Configuration Guide for the instructions to configure
the device.
If the problem continues, contact Enterasys Networks
for technical support.
Table 4-2 Troubleshooting Checklist (Continued)
Problem Possible Cause Recommended Action
Caution: Do not remove a DFE-Diamond modulefrom an operating chassis system before reading
the following information and instructions.
Precaución: Antes de retirar los módulos DFE-Platinum del chasis en funcionamiento, lea las
siguientes instrucciones y la información suministrada.