EPoX Computer EP-6VBA Personal Computer User Manual


 
BIOS
EP-6VBA
Page 4-23
CPU Host Clock (CPU/PCI):
Allows the external clock to be modified depending upon what FSB has been
selected. Should not be used to clock processor faster than it was designed for.
(See page A-11).
The default is Default.
66MHz FSB options: Default, 66.8, 68.5, 75, and 83MHz.
100MHz FSB options: Default, 100, 103, 112, and 133MHz.
DRAM Clock Is:
The item will synchronize/asynchronize DRAM operation clock.
Host Clock: DRAM has same working clock with CPU host bus.
2/3 Host: DRAM running with lower operation clock.
CPUFAN Off In Suspend:
This option is used to set if the CPU fans will turn off during suspend mode.
The default is Enabled.
Enabled: The system will turn off the CPU fans during suspend mode.
Disabled: The system will not turn off the CPU fan during suspend mode.
Current System Temp:
This is the Current temperature of the system.
Current CPU Temperature:
This is the current temperature of the CPU.
Current CPU FAN Speed:
The current CPU fan speed in RPMs.
Current Chassis FAN Speed:
The current chassis fan speed in RPMs.
CPU(V):
The voltage level of the CPU(Vio/Vcore).
Vtt, +3.3V, +5V, +12V: The voltage level of the switch power supply.