Epson ES-600C Scanner User Manual


 
The Condition Data-Block
The GT-6500 sends the following data-block when it receives the
ESC S (Request condition) command.
Condition Data-Block
Order of
bytes
Data
(in hex)
Contents Explanation
(Information block)
1 02 STX code Header: indicates the beginning of
the data-block
2 xx* Status Status byte: indicates the status of
the scanner
3 21 33 Bytes Byte counter: indicates the number
of bytes of data
4 00
(Data)
1 43 ‘‘C’’ Color mode
2 xx i
3 52 ‘‘R’’ Resolution
4 xx n1 (main scan resolution)
5 xx
6 xx n2 (sub scan resolution)
7 xx
8 41 ‘‘A’’ Reading area
9 xx n1 (main scan offset length)
10 xx
11 xx n2 (sub scan offset length)
12 xx
13 xx n3 (main scan read length)
14 xx
15 xx n4 (sub scan read length)
16 xx
17 44 ‘‘D’’ Data format
18 xx i
19 42 ‘‘B’’ Halftoning mode
20 xx i
Scanner Model Technical Data B-41