Epson RX-8564LC Clock User Manual


 
RX8564 LC
Page33
ETM12E-01
13.6.3. Starting and stopping I2C bus communications
SCL
START
condition
SDA
1
s ( Max. )
Repeated START(RESTART)
condition
STOP
condition
[ S ]
[ Sr ] [ P ]
1) START condition, repeated START condition, and STOP condition
(1) START condition
The SDA level changes from high to low while SCL is at high level.
(2) STOP condition
This condition regulates how communications on the I
2
C-BUS are terminated.
The SDA level changes from low to high while SCL is at high level.
(3) Repeated START condition (RESTART condition)
In some cases, the START condition occurs between a previous START condition and the next STOP
condition, in which case the second START condition is distinguished as a RESTART condition. Since the
required status is the same as for the START condition, the SDA level changes from high to low while SCL
is at high level.
2) Caution points
1) The master device always controls the START, RESTART, and STOP conditions for communications.
2) The master device does not impose any restrictions on the timing by which STOP conditions affect
transmissions, so communications can be forcibly stopped at any time while in progress. (However, this is
only when this RTC module is in receiver mode (data reception mode = SDA released).
3) When communicating with this RTC module, the series of operations from transmitting the START
condition to transmitting the STOP condition should occur
within 1 seconds
. (A RESTART condition may
be sent between a START condition and STOP condition, but even in such cases the series of operations
from transmitting the START condition to transmitting the STOP condition should still occur
within 1
seconds
.)
If this series of operations requires
1 seconds or longer,
the I
2
C bus interface will be automatically
cleared and set to standby mode by this RTC module's bus timeout function. Note with caution that both
write and read operations are invalid for communications that occur during or after this auto clearing
operation. (When the read operation is invalid, all data that is read has a value of "1").
Restarting of communications begins with transfer of the START condition again
4) When communicating with this RTC module, wait
at least 1.3 µs (see the tBUF rule)
between transferring
a STOP condition (to stop communications) and transferring the next START condition (to start the next
round of communications).
SCL
SDA
1.3
µ
µµ
µ
s (Min.)
STOP
condition
START
condition
[ P ]
[ S ]