4-8 Reference Information
Interface Specifications
Note:
The interface is a factory-installed option. One of the following
interfaces is already installed: RS-232, RS-485, or parallel.
See the EPSON TM-U200 Series (Type A) Specification for details.
Drawer Kick-out Specifications
Serial interface:
RS-232 compatible or RS-485 compatible
Parallel interface:
IEEE 1284 compatible (Nibble/Byte
Modes)
Pin No. Signal Name Direction
1Frame GND —
2 Drawer kick-out drive signal 1 Output
3 Drawer open/close signal Input
4 +24 V —
5 Drawer kick-out drive signal 2 Output
6 Signal GND —
Output signal voltage:
Approximately 24 V
Output current:
1 A or less
Solenoid resistance:
24 Ω or more