1.4 General Specifications
1.4.1 Electrical Specifications
Note 1: If the printer or scanner is not operated for more than three minutes, the printer goes
into the power save mode within two minutes.
1.4.2 Environmental Conditions
Note *1 : The combined Temperature and Humidity conditions must be within the blue-shaded
range in
Fig.1-4.
*2 : No condensation
*3 : 1 mouth at 40°C
120 hours at 60°C
Figure 1-4. Temperature/Humidity Range
Table 1-10. Primary Power Specifications
Item 100-120 V model 220-240 V model
Rated power supply voltage 100 to 120 VAC 220 to 240 VAC
Input voltage range 90 to 132 VAC 198 to 264 VAC
Rated current (Max. rated current) 0.6 A (TBD A) 0.4 A (TBD A)
Rated frequency 50 to 60 Hz
Input frequency range 49.5 to 60.5 Hz
Insulation resistance
1500 VAC for one minute
(between AC lines and chassis)
Insulation resistance
Higher than 10 M Ω at 500 VDC
(between AC lines and chassis)
Energy conservation International Energy Star Program compliant
Power
consumption
Standby (Max, when
Power off)
1 W 1 W
Sleep (Max) 3.8 W 3.8 W
Copying (Normal BK
mode, Typ.)
11.7 W 11.5 W
Copying (Draft BK
mode, Max.)
22.1 W 22.4 W
Table 1-11. Environmental Conditions
Condition Temperature
*1
Humidity
*1,2
Shock Vibration
Operating
10 to 35°C
(50 to 95
°F)
20 to 80%
1G
(1 msec or less)
0.15G,
5
to 55Hz
Storage
(in carton box)
-20 to 60°C*
3
(-4°F to 140°F)
5 to 85%
2G
(2 msec or less)
1.5G,
5
to 55Hz
C A U T I O N
When returning the repaired printer to the customer, make sure
the Printhead is covered with the cap and the ink cartridge is
installed.
If the Printhead is not covered with the cap when the printer is
off, turn on the printer with the ink cartridge installed, make
sure the Printhead is covered with the cap, and then turn the
printer off.
10/50
27/80
35/9520/68
Temperature (°C/°F)
20
30
40
50
90
80
70
60
Humidity (%)
30/86 40/104