36 XTP CrossPoint 1600 and 3200 • Remote Control 37XTP CrossPoint 1600 and 3200 • Remote Control
NOTE:
X@
= Output number 01 – 16 or 32
X1)
= Mute 0 = off (unmuted) 1 = on (muted)
X2%
= Video and audio mute 0 = no mute 1 = video mute 2 = audio mute 3 = video and audio mute
Command SIS Command
(Host to Unit to Endpoint)
Response
(Endpoint to Unit to Host)
Additional Description
Audio mutes
Audio mute, HDMI and S/PDIF
X@
*1Z Amt
X@
*1
]
Mute output
X@
embedded digital (audio off).
Audio mute, analog
X@
*2Z Amt
X@
*2
]
Mute output
X@
analog (analog audio off).
Audio mute, both
X@
*3Z Amt
X@
*3
]
Mute all output
X@
audio (digital and analog audio off).
Audio unmute
X@
*0Z Amt
X@
*0
]
Unmute output
X@
(digital and analog audio on).
Read audio mute
X@
Z
X1)]
1 = mute on, 0 = mute off.
Global audio mute, HDMI and
S/PDIF
1*Z
Amt1
]
Mute all embedded digital audio outputs.
Global audio mute, analog
2*Z
Amt2
]
Mute all analog audio outputs.
Global audio mute, both
3*Z
Amt3
]
Mute all embedded digital and analog audio outputs.
Global audio unmute
0*Z
Amt0
]
Unmute all audio outputs.
View video and audio mutes
View output mutes
E
VM
}
X2%
1
X2%
2
...
X2%
n
]
Each
X2%
response is the mute status of an output,
starting from output 1. n = either 16 or 32.
Example :
(XTP CrossPoint 3200)
E
VM
}
Audio is muted on outputs 2 and 3, video on
output 5, and video and audio on output 26. All
other outputs are unmuted.
Mut02201000000000000000000003000000
]
Command SIS Command
(Host to Unit to Endpoint)
Response
(Endpoint to Unit to Host)
Additional Description
Relay controls
Turn on an endpoint relay
EX@
*
X2^
*1RELY
}
Rely
X@
*
X2^
*1
]
Turn on relay
X2^
in output
X@
.
Turn off an endpoint relay
EX@
*
X2^
*0RELY
}
Rely
X@
*
X2^
*0
]
Turn off relay
X2^
in output
X@
.
Toggle an endpoint relay
EX@
*
X2^
*2RELY
}
Rely
X@
*
X2^
*2
]
Toggle (on-to-off or off-to-on) relay
X2^
in output
X@
.
Pulse an endpoint relay
EX@
*
X2^
*3*
X2&
RELY
}
Rely
X@
*
X2^
*3*
X2&]
Turn on relay
X2^
in output
X@
for an interval dened
as
X2&
. Each step of
X2&
is 16 ms.
Example:
E
1*2*3*45RELY
}
Rely1*2*3*45
]
Turn on relay 2 in output endpoint 1 for 720 ms
(0.72 sec,
X2&
= 45 * 16 ms = 720 ms).
View an endpoint relay status
EX@
*
X2^
RELY
} X2*]
On or off.
NOTE:
X!
= Input number 01 – 16 or 32
X2^
= Relay on endpoint 1 or 2
X2&
= Pulse duration 0 through 65535 (each step = 16 ms, see the example above)
X2*
= Relay status 0 = Off 1 = On