10 XTP CrossPoint 1600 and 3200 • Installation 11XTP CrossPoint 1600 and 3200 • Installation
XTP CP 4o HDMI (HDMI output board)
OUT
XTP CP 4o HDMI
AUDIO
LR LRLR LR
OUT
2e2e 2e2e 2f
2e
HDMI connectors — Connect an HDMI video display
to each of these ports.
NOTE: See HDMI connectors on page 14 to secure the
connector to the board with a LockIt HDMI Cable Lacing
Bracket.
2f
Audio (local audio) connectors — Connect audio
LR
devices, such as audio ampliers or powered speakers
to these 3.5 mm, 5-pole captive screw connectors to
receive unamplied, line level audio (see Local audio
connectors on page 15 to wire the connectors).
XTP CP 4o DVI Pro (DVI Pro output board)
OUT
XTP CP 4o DVI Pro
AUDIO
LR LRLR LR
OUT
2g2g 2g2g 2h
2g
DVI connectors — Connect a DVI video
display to each of these ports.
2h
Audio (local audio) connectors — Connect audio
LR
devices, such as audio ampliers or powered speakers
to these 3.5 mm, 5-pole captive screw connectors to
receive unamplied, line level audio (see Local audio
connectors on page 15 to wire the connectors).
XTP CP 4o SA (Analog audio output board)
OUT
XTP CP 4o SA
AUDIO
LR LRLR LR
OUT
2i
2i
Audio (local audio) connectors — Connect audio
LR
devices, such as audio ampliers or powered speakers
to these 3.5 mm, 5-pole captive screw connectors to
receive unamplied, line level audio (see Local audio
connectors on page 15 to wire the connectors).
Remote Control
c
LAN (Ethernet) port — If desired, connect a network WAN or LAN
hub, a control system, or a computer to the Ethernet RJ-45 port (see
TP connectors on page 12 to wire the connector).
NOTE: The factory default IP address is 192.168.254.254.
d
Remote RS-232/RS-422 port — If desired, connect a third-party
control system or computer to the rear panel Remote RS-232/RS-422
port (see Remote port connector on page 16 to wire the
connectors).
NOTE: The XTP System Configuration software CANNOT
interface with the switcher via the Remote RS-232/RS-422
port. A third-party control system or a computer issuing SIS
commands can use this port.
Reset
e
Reset button — Initiates four levels of reset of the matrix switcher.
For different reset levels, press and hold the recessed button while
the switcher is running or while you power up the switcher.
See the XTP CrossPoint 1600 and 3200 Series User Guide, available
on the Extron DVD or at www.extron.com.
Power
f
Power connectors — Plug the switcher into a grounded AC
source.