Extron electronic IPL T PC1I Power Supply User Manual


 
Command
ASCII (Telnet)
(Host to Switcher)
URL Encoded (web)
(Host to Switcher)
Response
(Switcher to Host)
IP Setup Commands (continued)
Set GMT offset
24
E
X#
CZ
}
W
X#
CZ
|
Ipz
X#
]
View GMT offset
E
CZ
}
W CZ
| X#
]
Set daylight savings time
24
E
X3$
CX
}
W
X3$
CX
|
Ipx
X3$
]
View daylight savings time
E
CX
}
W CX
| X3$
]
Set DHCP on
24
E
1DH
]
W 1DH
|
Idh1
]
Set DHCP off
24
E
0DH
]
W 0DH
|
Idh0
]
NOTE: Changing DHCP from On to Off resets the IP address to the factory default (192.168.254.254).
View DHCP mode
E
DH
]
W DH
| X%
]
Set IP address
24
E
X1$
CI
}
W
X1$
CI
|
Ipi
X1$
]
View IP address
E
CI
}
W CI
| X1$
]
View hardware (MAC) address
E
CH
}
W CH
| X1*
]
With tagged response –
verbose modes 2 and 3:
Iph
X1*
]
Set subnet mask
24
E
X1(
CS
}
W
X1(
CS
|
Ips
X1(
]
View subnet mask
E
CS
}
W CS
| X1(
]
Set gateway IP address
24
E
X1$
CG
}
W
X1$
CG
|
Ipg
X1$
]
View gateway IP address
E
CG
}
W CG
| X1$
]
Set verbose mode
24
NOTE: The IPL T PC1 can send out unsolicited information (such as notice of a power level change). This is called a
verbose (wordy) relationship between the interface and a connected device. When the IPL T PC1 is connected to
the computer via Ethernet, verbose mode is disabled (by default) in order to reduce the amount of communication
traffic on the network. If you want to use the verbose mode with the PC1 connected via Ethernet, you must set
verbose mode to On each time you reconnect the computer to the network.
E
X2@
CV
}
W
X2@
CV
|
Vrb
X2@
]
View verbose mode status
E
CV
}
W CV
| X2@
]
Set broadcast mode
E
X6$
,
X1$
EB
}
W
X6$
%2C
X1$
EB
|
Bmd
Set broadcast mode to default
address
E
X6$
EB
}
W
X6$
EB
|
Bmd
X6$
,
X1$
]
Clear broadcast mode
E
0EB
}
W 0EB
|
Bmd 000,
X1$
]
View broadcast mode
E
EB
}
W EB
| X6$
,
X1$
]
Set broadcast port and MAC
address
E
port number*
X7!
*
X7@
PB
}
W port number*
X7!
*
X7@
PB
|
Bpt port number*
X1*
]
View broadcast port and MAC
address
E
PB
}
W PB| port number*
X1*
]
NOTE: Port number is the UDP outgoing port.
X7!
*
X7@
is the MAC address for UDP unicast transmissions.
Get connection listing
E
CC
}
W CC
|
Number of
connections
]
With tagged response –
verbose modes 2 and 3:
Icc Number of
connections
]
IPL T PC1 • SIS Programming and Control 57