Extron electronic MAV Plus Switch User Manual


 
3-25
CrossPoint 450 Plus and MAV Plus Switchers • Operation
PRELIMINARY
2. Press and hold the RGBHV button for approximately 2 seconds (fi gure 3-36).
RGBHV RGBHV
Press and hold the RGBHV button until it blinks.
2 seconds
= Blinking button
Figure 3-36 — Select RGB Delay mode
3. Press and release the output 17 button (fi gure 3-37).
17 18 19
1 2 3
O
U
T
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
26
10
27
11
I
N
Press and release the
Output 17 button.
The button lights green.
The Input 1 through Input 10 buttons display the selected output's RGB delay.
Each lit input button indicates half a second of delay.
In this example, the green input buttons display 3.5 seconds of RGB delay.
3.5 3.0 2.5 2.0 1.5 1.0 0.5
= Unlit button = Lit button
Figure 3-37 — Select an output
4. Press and release the Esc (
>
) button once (fi gure 3-38) to increase the RGB
delay by a half second.
Press and release the Esc (
>
) button twice more to increase the RGB delay by a
whole second. Note the input button indication changes that occur each time
the Esc (
>
) button is pressed and released.
Figure 3-38 show the result of pressing the Esc (
>
) button a total of 3 times.
ESC ESC ESC
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
26
10
27
11
I
N
3.5 4.0 4.5 5.03.02.52.01.51.00.5
1
Press the Esc button to increase the RGB interval that is applied to switches to
the selected output by a half second per button push.
= Unlit button = Lit button
The Input 1 through Input 10 buttons display the selected output's RGB delay.
Each lit input button indicates half a second of delay.
In this example, the green input buttons display 5.0 seconds of RGB interval.
Figure 3-38 — Adjust the RGB delay interval
N
You can press and hold the Esc (
>
) or View (
<
) button to ramp the delay up or
down to the high or low limit.