Extron electronic MAV Plus Switch User Manual


 
4-13
CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Save, recall, and directly write presets
N
• If the user tries to recall a preset that is not saved, the matrix switcher responds with the error code E11.
If the room is nonexistent, the matrix switcher responds with the error code E21.
The following characters are invalid in preset names: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
Save current the current
confi guration as a global
preset
X1!
, Spr
X1!]
Command character is a
comma.
Example:
9,
Spr09
]
Save current ties as preset 9.
Direct write process —
N
The direct write of a global preset command should always be preceded by a clear global preset command of that
same preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied output)
remains unchanged unless overwritten or cleared.
If you do not clear a global preset number before you directly write a global preset to that number, ties that are part of
the previous version of the specifi ed preset can unexpectedly become part of the newly-created preset.
Clear a global preset
E
+
X1!
P0*!
}
Spr
X1!]
Clear all ties in preset
X1!
.
Directly write a global
preset
E
+
X1!
P
X@
*
X#
!
X@
*
X#
%
X@
*
X#
$ ...
X@
*
X#
&
}
Enter as many ties as are
valid for this model. The
tie all (!), tie RGBHV (&), tie
video (%), and tie audio ($)
commands are all valid.
Spr
X1!]
Example:
E
+27P0*!
}
Spr27
]
Brackets are shown to
separate ties for clarity only.
Create global preset 27,
which ties video and audio
input 22 to output 5,
RGBHV input 15 to output 29,
video input 13 to output 26,
and audio input 3 to output 8.
E
+27P22*5!15*29%13*26$3*8&
Spr27
]
Recall a global preset
X1!
. Rpr
X1!]
Command character is a
period.
Example:
5.
Rpr
X1!]
Recall preset 5, which
becomes the current
confi guration.
Write room outputs
EX*
,
Y!
,
Y@
,
Y#
, ...,
Y/
MR
}
See notes.
Mpr
X*
,
Y!
,
Y@
,
Y#
, ...,
Y/]
N
Each
Y`
is an output.
A room can contain a maximum of 16 outputs (
Y`
s).
An output can belong to one room only.
The maximum number of rooms (
X*
) is 10.
If no room name is assigned, the dafault name is “Room #
X*•Y!
,
•Y@
,
•Y#
”.
Example:
E
8,3,04,5,6MR
}
Mpr8,03,04,05,06
]
Outputs 3, 4, 5, and 6 are
assigned to room 8.
Read room outputs
EX*
MR
} X2!
,
Y!
,
Y@
,
Y#
, ...,
Y/]
Example:
E
3MR
}
Class 1,01,02,08,09
]
Outputs 1, 2, 8, and 9 are
assigned to room 3, which is
named “Class 1”.
Save current confi guration
as a room preset
X*
*
X1@
, Rmm
X*•
Spr
X1@]
Command character is a
comma.
Example:
3*9,
Rmm03
Spr09
]
Save the current
confi guration as preset 9 for