Extron electronic MTP Switch User Manual


 
VersaTools
®
MTP Series • Installation
VersaTools
®
MTP Series • Installation
Installation
2-3
SHARP
GAIN
Figure 2-1 — Removing the MTP cover
2. For the receiver, slide the cover slightly forward to clear
the front panel adjustment knobs.
3. Lift the cover straight up.
4. If the transmitter or receiver is an audio unit, remove and
retain the two screws that secure the audio board to the
main (video) board (figure 2-2). Pull the audio board back
until the audio connectors clear the back of the unit and
lift the board out of the way.
Step 4 and figure 2-2 are correct for either S-video or
composite video models.
Transmitter Front Panel Receiver Front Panel
Receiver Rear PanelTransmitter Rear Panel
Remove these screws.
Figure 2-2 — Removing the audio board
CAUTION
Installation and service must be performed by
authorized personnel only.
Signal Jumpers for Generational Compatibility
Over time, the MTPs have been redesigned, affecting the signal
content of the TP cable wire pairs, changing the audio from
stereo to mono, and eliminating the remote power capability.
The new-generation units are not compatible with the old
generation unless an internal jumper in the new unit is shifted.
Shift the new transmitter’s and/or receiver’s jumpers if:
Your installation mixes a transmitter and receiver from
different generations.
You want the units to transmit stereo audio.
You want one unit to remotely power another.
Use the table below to identify the generation (revision level) of
the transmitter and receiver in your installation. If any of the
above scenarios are true, reconfigure the units’ jumpers before
mounting the units.
Only the new generation units have these jumpers.
Transmitter Old generation New generation
part # part #
MTP T SV 60-540-02 60-540-42
MTP T SV A 60-540-22 60-540-52
MTP T SV A RCA 60-541-32 60-540-62
MTP T SV A AAP 70-362-02, -03 70-362-22, -23
MTP T CV 60-540-01 60-540-41
MTP T AV 60-540-21 60-540-51
MTP T AV RCA 60-540-31 60-540-61
MTP T AV AAP 70-361-02, -03 70-361-22, -23
Receiver Old generation New generation
part # part #
MTP R SV 60-541-02 60-541-42
MTP R SV A 60-541-22 60-541-52
MTP R SV A RCA 60-541-32 60-541-62
MTP R CV 60-541-01 60-541-41
MTP R AV 60-541-21 60-541-51
MTP R AV RCA 60-541-31 60-541-61
Setting the jumpers on non AAP models
1. Remove and retain the four screws (two on each side of
the unit) that secure the cover to the MTP (figure 2-1).
2-2