The PFC version connection is shown in Figure 3-2. Connect the input voltage line
wires to L2 and COM terminals.
WARNING: 152A and 202A PFC Models are only available with 220 VAC
Nominal. For 152A Models Suffix 110 at 110-120 VAC must be operated
with the internal fuses F1 and F2 (on the Inverter Board) replaced by
copper bus provided with the supply. Use external 30A UL/VDC Approved
Fuse/Circuit Breaker.
NOTE: For Application At less than 10 Hz Please see section 5.7.
TB1
L1
COM
L2
220 VAC
110 VAC
Figure 3-1 Input AC Power Connection NON-PFC Version
TB1
L1
COM
L2
VAC
Figure 3-2 Input AC Power Connection, PFC Version


3
33
32:(5&
2:(5&2:(5&
2:(5&25'6
25'625'6
25'63(&,),&$7,21
3(&,),&$7,213(&,),&$7,21
3(&,),&$7,21
Use wire with minimum .064 inches (1.6 mm) diameter and 600 V insulation.
83-493-001 Revision G
3 - 2 Installation