Fluke pmn Power Supply User Manual


 
2.23.4 SUFFIX -EN
"Low Enable" - A +10 to 15 volt (high) signal will disable power supply operation. A 0 to
+1.5 volt (low) signal will enable the supply.
2.23.5 SUFFIX -5V
0 to +5 volt voltage (0 to full-scale output) programming
2.23.6 SUFFIX -LP
Latching overload protection.
2.23.7 SUFFIX -110
100 to 120 VAC input option for non-power factor corrected 152A (1500 J/s) model.
NOTE: 152A power supply with suffix 110 at 100-120VAC
must be operated with internal 20A fuses F1 & F2 (on inverter bd)
replaced by copper bus provided with the supply. Use external
30A UL/VDC approved fuse/circuit breaker.



 2
22
25,(17$7,21
5,(17$7,215,(17$7,21
5,(17$7,21
Power supplies >6kV with Oil H.V. section must be operated in upright position. i.e. The
mounting bracket is parallel to the ground plane.
83-493-001 Revision G