You can use the CLI or Web management interface to do the following:
Display the temperature of the device
Change the warning and shutdown temperature levels
Change the device poll time
NOTE: Fan speed temperature threshold cannot be changed in the first release of the FastIron LS.
Displaying the Temperature on the FastIron LS
By default, the software polls the temperature sensor every 60 seconds to get the current temperature. This poll
rate is controlled by the device poll time, which also controls how often the software polls other system
components.
To display the temperature of a device, enter the following command at any level of the CLI:
Syntax: show device
Displaying Syslog Messages for Temperature on the FastIron LS
The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or shutdown
thresholds. The following methods describe how to view the system log on the device. If you have configured the
device to use a Syslog server or SNMP trap receiver, see the documentation for the server or receiver.
FLS648 Switch> show chassis
Power supply 1 not present
Power supply 2 (NA - AC - Regular) present, status ok
Fan 1 failed
Fan 2 failed
Fan 3 failed
Exhaust Side Temperature Readings:
Current temperature : 31.0 deg-C
Warning level.......: 45.0 deg-C
Shutdown level......: 55.0 deg-C
Intake Side Temperature Readings:
Current temperature : 27.5 deg-C
Boot Prom MAC: 000a.fae1.a189