Foundry Networks LS 648 Switch User Manual


 
Hardware Specifications
September 2007 © 2007 Foundry Networks, Inc. 2 - 11
Input Connector
Regulatory Compliance
This section contains regulatory standards for the power supplies, including the following:
Electromagnetic Compatibility (EMC) compliance
Immunity regulations
Safety certifications
Safety warning labels
Environmental standards
Electromagnetic Compatibility (EMC) and Immunity Standards
The power supplies comply with the conducted and radiated test and immunity standards as listed in Table 0.16.
EMC standards are within a 6 dB minimum margin.
FCC CFR 47 Part 15 Warning:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
Table 0.15: Input Connector for Power Supplies
Power Supply Input Connector Properties
RPS2-EIF IEC socket 216C743-07)
C14 type: UL File No.: E29179,
CSA File No.: LR19980
Table 0.16: EMC and Immunity Standards for Power Supplies
Power Supply EMC Standards Immunity Standards
RPS2-EIF ICES-003, Electromagnetic Emission
FCC Part 15 Class A
EN 55022/CISPR 22 Class A
VCCI Class A
EN 61000-3-2, Power Line Harmonics
EN 61000-3-3, Voltage Fluctuation &
Flicker
EN 61000-6-3, Electromagnetic
Compatibility, Generic Standard
AS/NZS CISPR 22, Electromagnetic
Compatibility
Harmonic Current Emissions (Class A) -
EN61000-3-2, with Amendment 14 (1999)
EN 61000-6-1, Electromagnetic
Compatibility, Generic Standard
EN 55024, Information Technology
equipment - Immunity Characteristics