Hot-plug components
I The two connection blades within a fabric must have the same
technology, i.e. either Ethernet or Fibre Channel or Infiniband.
When filling the slots in fabrics 2, 3 and 4, also make sure the server blades are
fitted with the appropriate mezzanine cards. The following rules apply for fitting
the mezzanine card slots of the server blades:
If a 1 Gb Ethernet mezzanine card is installed in slot 1 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in fabric 2 of the
system unit.
If a 10 Gb Ethernet mezzanine card is installed in slot 1 of a server blade, at
least one 10 Gb Ethernet connection blade must be installed in fabric 2 of
the system unit.
If an FC mezzanine card is installed in slot 1, at least one FC connection
blade must be installed in fabric 2.
If an Infiniband mezzanine card is installed in slot 1, an Infiniband connection
blade must be installed in fabric 2.
I In this case, only one of two channels of the Infiniband mezzanine
card is used.
If a 1 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in fabric 3 or in
fabric 4 of the system unit.
If a 10 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in fabric 3 of the
system unit.
If an FC mezzanine card is installed in slot 2, at least one FC connection
blade must be installed in fabric 3.
If an Infiniband mezzanine card is installed in slot 2, Infiniband connection
blades should be installed in fabrics 3 and 4.
I In this case, both channels of the Infiniband mezzanine card are
used.
You can install a combination of FC, Ethernet and Infiniband mezzanine
cards in a server blade. In this case, the Ethernet mezzanine card should be
installed in slot 1 and the FC or Infiniband mezzanine card in slot 2 of the
server blade.