Appendix A Racks
A.1 Rack Mounting
35
C122-H007-01EN
Appendix A Racks
This appendix provides various information on the mounting racks for the PRIMEQUEST 2000 series and
PCI_Box.
A.1 Rack Mounting
The PRIMEQUEST 2000 series (including peripheral devices) has been developed and its operation
guaranteed with the basic assumption that it is mounted in a Fujitsu rack. For safe use of a unit mounted in a
Fujitsu rack, contact the distributor where you purchased your product, or your sales representative.
When mounting the PRIMEQUEST products in a rack manufactured by another company, customers need
to confirm on their own responsibility that the rack meets the PRIMEQUEST product specifications and
requirements.
See A.2.2 Requirements for mounting in a rack manufactured by another company.
A.2 Rack Mounting Requirements
This section describes rack mounting requirements.
A.2.1 Requirements for mounting in a Fujitsu 19-inch rack
This section explains the requirements for mounting in a Fujitsu 19-inch rack. For safe use of the
PRIMEQUEST 2000 series server mounted in a Fujitsu 19-inch rack, observe the mounting requirements
described below.
Recommended racks for mounting
The following table lists the recommended racks for mounting the PRIMEQUEST 2000 series server and
PCI_Box.
TABLE A.1 Recommended racks for mounting
Fujitsu 19-inch rack
Depth (mm)
Open area ratio
Model 2742
1,050
80%
Model 2737
1,050
80%
Model 2724
1,050
80%
Model 2642
1,050
80%
Model 2624
1,050
80%
Model 2616
1,050
75%
PCR M1 742S
1,050
80%
PCR M1 724S
1,050
80%
PCR M1 642S
1,050
75%
PCR M1 624S
1,050
75%
PCR M1 616S
1,050
75%
PCR M1 742A
1,050
80%
PCR M1 724A
1,050
80%
TABLE A.2 PRIMEQUEST 2000 series external dimensions
Model
Height
Width
Depth
PRIMEQUEST 2000 series
438 mm (10U)
445 mm
782 mm
Note
The Fujitsu 19-inch rack comes with a blank panel covering the front of each empty space that has no
mounted device.
If warm exhaust air from the device circulates to the front of the rack and reenters the device, it may cause a
temperature alarm and lead to a device failure.
Be sure to use the blank panel to cover the front of an empty space that has no mounted device.