REPLACEMENT
OF PARTS
a)Remove the pick spring.
b)Remove the pad from the pad holder.
c)Attach a new pad to the pad
holder and fix it with the pick spring.
4-3
Close the ADF.
Attach the pad ASY to the ADF
until it clicks in the reverse
sequence of step 3.
Pad holder
Pad
Pick spring
NOTE
• Turn the pad upside down so that the pad
holder pin fits with the pad hole.
• Do not alter the shape of the pick spring.
• Attach the pick spring so that both ends of
the pick spring are located on the pad.
NOTE
Normally, set the select lever to “N”. Return the select
lever if necessary.
If the Pad is attached to the scanner,
you can replace the Pad according to
the following procedure.
4
5
Fit the pad ASY pin with the larger hole then
slide to the right.
NOTE
6