Fujitsu MAB3045 Computer Drive User Manual


 
C141-E035-02EN5 - 10
5.3.4 Mode settings
In addition to the previously described settings using setting terminals, the IDD is provided
with several mode settings. The mode settings are enabled by specifying the CHANGE
DEFINITION command. Table 5.6 lists the mode settings and their settings at factory
shipment.
Refer to Section 3.1.4 of the SCSI Logical Interface Specifications for details of the command.
Table 5.6 Default mode settings (by CHANGE DEFINITION command)
Mode setting Contents
SCSI level SCSI-2
SYNCHRONOUS DATA TRANSFER REQUEST message
sending
Sent from IDD
UNIT ATTENTION report mode Reported
Reselection retry count Not restricted
WIDE DATA TRANSFER REQUEST message sending Sent from IDD
Reselection time-out delay 250 ms
Spindle motor start delay time
0 sec (MAx3xxxSP)
12 sec × SCSI ID
(MAx3xxxSC)