1. OPERATION
7
1.8.3 Disabling timer operation when awaiting reception
Timer programs may be deleted from the timer reception schedule as follows.
1. Press the PRG key, and the message shown below appears.
2. Press the E key.
1.8.4 Unlocking the keyboard during timer reception
All keys except the PRG key are locked during recording to prevent accidental adjustment of the
equipment. If you need to operate the keyboard when timer reception is active, do the following:
1. Press the PRG key, and the following screen appears.
2. Press the E key to unlock the keyboard.
1.8.5 Confirming timer programs
Do the following to confirm timer programs that you have entered.
1. Press the PRG key and the 2 key to show the timer reception setting mode.
2. Press the 3 key to choose RCL (Recall).
3. Use the S or T key to choose timer program number, and the contents of the timer program
selected are displayed.
4. Press the C key several times to return to the standby display.
TIMER RCV : OFF?
PUSH E KEY
KEY LOCK : OFF?
PUSH E KEY
RECALL TIMER REG
SET REG No. 0-F