GarrettCom 6K25e Switch User Manual


 
Magnum 6K25e Gigabit Fiber Switch Installation and User Guide (10/07)
21
www GarrettCom com
..
The Dual Giga option on each of the two slot add 4 Gigaport to handle the bandwidth
requirement and 16 10/100 RJ-45 ports to feed the other needs of equipment connected to
the 6K25e. The robust Tag based vlan feature will able to segregates different ports
belong to one group and provide an effective solution for bandwidth. The SNMP option
and secure web based will allow the remote capability and monitoring the network
securely. The versatile mechanical design with rack mounting capability and AC/DC
option will be an additional feature to take care of temperature and power option issue.
Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K25e to
meet the fastest growing application of video monitoring or video surveillance
demand of industry and provide an economical and effective solution to meet
that expectation.
3.0 Installation
Before installing the equipment, it is necessary to take the
following precautions:
1.)
If the equipment is mounted in an enclosed or multiple rack
assembly, the environmental temperature around the equipment
must be less than or equal to 50
0
C.
2.)
If the equipment is mounted in an enclosed or multiple rack
assembly, adequate airflow must be maintained for proper and
safe operation.
3.)
If the equipment is mounted in an enclosed or multiple rack
system, placement of the equipment must not overload or load
unevenly the rack system.
4.)
If the equipment is mounted in an enclosed or multiple rack
assembly, verify the equipment’s power requirements to prevent
overloading of the building/s electrical circuits.
5.)
If the equipment is mounted in an enclosed or multiple rack
assembly verify that the equipment has a reliable and
uncompromised earthing path.
6.)
24vdc, -48vdc, and 125vdc must be installed in restricted
access locations.
7.)
CB-Circuit breakers of 10Amps should be shown on top of the
Rack.
This section describes installation of the
Magnum 6K25e Switches, as well as connection of
the various Ethernet media types.
3.1 Locating Magnum 6K25e Switches
The location of a Magnum 6K25e Switch
is dependent on the physical layout of the network.
Typically the Switch is placed in a central wiring
location where groups of network devices need to
be connected in order to communicate with each
other. These Switches are typically rack mounted in
a wiring closet see Section 3.3.2 below), but
because they have rubber feet they can also be installed on a shelf or table top unit. The
compact size allows it to be easily placed in an office or lab area, and it can also be either
shelf of wall-mounted (see Section 3.3.1 below). Figure 3.1: Location of the Magnum
6K25e’s cooling fans