GarrettCom Magnum 6KQ Switch User Manual


 
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
22
www GarrettCom com
..
NOTE : It is recommended that high quality CAT. 5 cable be used whenever possible
in order to provide flexibility in a mixed-speed network, since 10/100 copper
switched ports are auto-sensing for either 10 and 100Mb/s.
The following procedure describes how to connect a 10BASE-T or 100BASE-
TX twisted pair segment to the RJ-45 port. The procedure is the same for both
unshielded and shielded twisted pair cables.
1. Using standard twisted pair media, insert either end of the cable with an RJ-45
plug into the RJ-45 connector of the port. Note that, even though the connector is
shielded, either unshielded or shielded cables and wiring may be used.
2. Connect the other end of the cable to the corresponding device
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established
NOTE: for Power Substations
: In support of the IEEE 1613 Class 2 standard, GCI
advises that, for substation applications, the RJ-45 ports are intended for
connectivity to other communication equipment such as routers or
telecommunication multiplexers installed in close proximity (i.e., less than 2
meters or 6.5ft) to the 6KQ. It is not recommended to use these ports in
substation applications to interface to field devices across distances which
could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)
during line-to-ground fault conditions. The 6KQ passes the 1613specifications
for zero packet loss with fiber ports & with RJ45 ports used as indicated here.
3.2.5 Connecting Twisted Pair (CAT5e or better, Unshielded or Shielded)
The RJ-45 Gigabit ports of the Magnum 6KQ can be connected to the media
types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
balanced cable is recommended to use when making 1000BASE-TX connections. In
either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).
Media
IEEE Standard Connector
Twisted Pair (CAT 5e) 1000BASE-T RJ-45
The following procedure describes how to connect a 1000BASE-T twisted pair segment
to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted
pair cables.
1. 1000BASE-T connections require that all four pairs or wires be connected. Insert
either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.
Note that, even though the connector is shielded, either unshielded or shielded
cables and wiring may be used.
2. Connect the other end of the cable to the corresponding device
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established