Gateway 820 LTO Network Card User Manual


 
44
Chapter 5: Troubleshooting and Diagnostics
www.gateway.com
Function errors
86 Access door cannot be opened, preventing the
removal of tape media.
87 Timeout. A timeout condition occurred.
88 Communications error during loop-back.
89 Timeout detected by loader on BHC testing.
8F No error after autoloader recovery.
Error code hex
notation
Description
90 Mechanical initialization failure. The robotic was not
able to get into its safe mechanical init position. Manual
intervention will be necessary.
91 Scan failure. Fatal error during cartridge scan, building
up inventory.
92 Preposition failed. Belt positioning error during
’Preposition’ command.
93 Cartridge mount error. Movement of cartridge into drive
failed.
94 Cartridge dismount error. Failure during cartridge
removal and transport back to the slot.
95 Import error. Device was not able to finish import of new
cartridge without error.
96 Export error. Fatal error during cartridge export.
Error code hex