Gateway server Server User Manual


 
CHAPTER 6: Troubleshooting
66
Troubleshooting
First steps
Try these steps first before going to the following sections:
Make sure that the power cords are connected to your server and an AC outlet and that
the AC outlet is supplying power.
If you use a surge protector or a UPS, make sure that it is turned on and is rated to handle
the power required by your server.
Voltage 1.8V Normal operating
range
1.7848 Volts
Voltage 1.2V Normal operating
range
1.2125 Volts
Temperature CPU0 Diode 1 Normal operating
range
25 deg. C
Temperature CPU0 Diode 2 Normal operating
range
25 deg. C
Temperature CPU1 Diode 1 Upper Non-recoverable 128 deg. C
Temperature CPU1 Diode 2 Upper Non-recoverable 128 deg. C
Temperature MCH Ambient Normal operating
range
22 deg. C
Temperature FBD Ambient Normal operating
range
25 deg. C
Temperature ESB2 Ambient Normal operating
range
22 deg. C
Processor CPU0 State Normal 1
Processor CPU1 State Normal 1
Physical Security Chas Intrusion Normal 0
Button UID BTN State Deasserted 0
Power Supply PS1 STATUS Unavailable
Power Supply PS2 STATUS Unavailable
Power Supply PS REDUNDANCY Unavailable
Power Unit Power Unit Normal 0
Watchdog 2 Watchdog2 Normal 0
Sys. Event SYS EVENT Normal 0
Warning
To avoid bodily injury, do not attempt to troubleshoot your server problem if:
- The power cords or plugs are damaged
- Liquid has been spilled into your server
- Your server was dropped
- The case was damaged
Instead, unplug your server and contact a qualified computer technician.
Sensor type Sensor name Sensor status Current reading