Programming the Scanner
3-12
Symbology Programming
♦ Code ID Transmission and Symbology Enable ♦
PROGRAM END(Exit)
Family Code Selection Parameter Selection Option Code
Code ID Transmission
Disable symbology ID transmission
Enable prefix symbology ID transmission
Enable suffix symbology ID transmission
Enable both prefix and suffix symbology ID transmission
0
1
2
3
Symbology Enable
Remember to scan
“FIN”
to terminate
this selection. But if you select the
“Automatic discrimination”
, scanner
will terminate this selection
automatically
.
Automatic discrimination
Code 128, UCC/EAN-128
UPC-A
UPC-E
EAN/CAN/JAN-13
EAN/CAN/JAN-8
Codabar/NW-7
Code 39/Code 32, HIBC
Code 2 of 5 Family, IATA
Code 93
Code 11
MSI/Plessey
UK/Plessey
Telepen
00
01
02
03
04
05
06
07
08
09
10
11
12
13
FACTORY DEFAULT
If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possibility by enabling
those known symbologies only. Furthermore, to add the “
Symbology ID
” into the transmitted data is also helpful for applications to identify the specific symbology
ID. For example, to enable UPC-A and Code 39, only scan the following bar codes: “PROGRAM,” “Symbology Enable,” “0,” “2,” “0,” “7,” “FIN” and “END.”
To further ensure fast, accurate readings, you can complete more complex configurations via full-feature the
Data Editor
. To configure the full-feature the Data
Editor, you must use the
HHP SET
, a Windows
®
95/98/NT based software utility specially designed for the scanner.