Hand Held Products 3220 Scanner User Manual


 
Programming the Scanner
3-26
PROGRAM
Wand Emulation Control
Output Polarity, Signal State, Margin/Module Time,
Narrow/Wide Ratio, Code 39 Emulation
END(Exit)
Family Code Selection Parameter Selection Option Code
Output Polarity
High level (5Vdc) on Bar (low level on Space)
Low level (0Vdc) on Bar (high level on Space)
Determine the output voltage level for both bar and space.
0
1
Initial Signal State
High Level (5Vdc)
Low Level (0Vdc)
Determine the initial state of output voltage level.
0
1
Margin Time
10 mseconds
15 mseconds
20 mseconds
25 mseconds
30 mseconds
50 mseconds
100 mseconds
Delay time before data transmission
0
1
2
3
4
5
6
Module Time
Extremely short
Short
Medium
Long
Time base of minimum narrow bar
0
1
2
3
Narrow/Wide Ratio
1:2
1:2.5
1:3
0
1
2
Code 39 Emulation
Disable standard Code 39 emulation
Enable standard Code 39 skip emulation
Enable standard Code 39 replace emulation
0
1
2
FACTORY DEFAULT
[ Code 39 Skip ] :
When this option is selected, all scanned data will be translated as Standard Code 39 wand emulation output. If any lowercase characters are
read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be
skipped
.
[ Code 39 Replace] :
Any character not normally available in the standard Code 39 symbology set will be translated as
Space
.