Programming the Scanner
3-13
Symbology Programming
♦ Code 39/Code 32 Settings♦
PROGRAM END(Exit)
Family Code Selection Parameter Selection Option Code
Code 39 Family Settings
Select Standard Code 39
Select Full ASCII Code 39*
Select Code 32 (Italian Pharmaceutical)
Disable start/stop symbol transmission
Enable start/stop symbol transmission
Disable Code 32 leading A transmission
Enable Code 32 leading A transmission
Disable MOD 43 check digit verification
Enable MOD 43 check digit verification
Disable check digit transmission
Enable check digit transmission
0
1
2
3
4
5
6
7
8
9
A
Code 39 Min. Length
Default (04)
Minimum length
Scan 2 digits from the option code chart in the Appendix.
(2 digits)
Code 39 Max. Length
Default (99)
Maximum length
Scan 2 digits from the option code chart in the Appendix.
(2 digits)
FACTORY DEFAULT
* Selecting Full ASCII Code 39 disables Code 32 (both options may not be enabled at the same time). Code 39 and full ASCII may be enabled at the same time, and
Code 32 and Code 39 standard my be enabled at the same time.