Configuration and Settings
Quick Check
®
PC software can be easily configured to meet one or more
application requirements. Following are the user-configurable settings.
Verification Parameters
Number of Scans
Set Scan Count
S
ettings, Scan
Right click Accumulated Scans display
• Select from 1 to 50 individual scans to produce the final grade (ISO/IEC
method).
Symbology Selection
Right Click Symbology display
• Select/deselect symbologies
• Select/deselect U.P.C. addendums
• Set U.P.C. magnification factor
Note: It is recommended that you enable only those symbologies you
need.
Note: Deselect code 128 when using UCC/EAN-128
Note: Select “Unrecognized” symbology only if you are checking
reflectance parameters of a symbology not supported by Quick Check
®
PC or
analyzing a “pattern.”
Scan Direction
Right Click Scan Direction display
• Select forward-only, reverse-only, or bidirectional scanning
Minimum Scan Grade
Right Click ISO/IEC Scan Grade display
• Set minimum symbol grade
Check Digit(s)
Right Click Check Digit Pass/Fail indicator
• Enable/disable verification of optional check characters
19