HP (Hewlett-Packard) 2 SP4 Computer Drive User Manual


 
SMA Configuration Guidelines
21Using Storage Area Manager on the Storage Management Appliance Application Notes
Storage Management Appliance Backup
Because Storage Area Manager and the SMA maintain separate databases, a backup of the
SMA will not normally include the Storage Area Manager backup data. If you want to include
the Storage Area Manager backed-up data in an SMA backup, you must take special steps as
described in “Configuring the SMA to Back Up Storage Area Manager.”
Configuring the SMA to Back Up Storage Area Manager
To include the Storage Area Manager backed-up data in an SMA backup, you must include the
Storage Area Manager backup database path in the SMA backup configuration file,
osmbackup.conf. The procedures for Storage Area Manager v3.0 and v3.1 are described below
with examples. If you accepted all of the default settings during installation of Storage Area
Manager, the examples are accurate for your configuration.
Storage Area Manager v3.0 backup configuration, below
Storage Area Manager v3.1 backup configuration, page 23
Storage Area Manager v3.0 backup configuration
To configure the SMA to include Storage Area Manager v3.0 backups:
1. Connect to the SMA, either through Terminal Services or by attaching a monitor,
keyboard, and mouse.
2. Use Notepad or another text editor to open the file, sanmgr.ini, which resides on the SMA
(for example, C:\WINNT\sanmgr.ini).
3. Find the ManagementRoot entry in the sanmgr.ini file to determine the Storage Area
Manager installation directory path.
In the example below, the installation directory path is
C:\program files\Hewlett-Packard\sanmgr\.
[CheckResult]
TotalPhysicalMemory=0402046976
FileSystemType=NTFS
AcrobatReader=AcroExch.Document
ProcessorSpeed=0731
[Setup]
ManagementRoot=C:\program files\Hewlett-Packard\sanmgr\
SourceRoot=\\SILCCRLS\RELEASE\SRM_REL\VERSI~A!\CDIMAGE\SAM30-MR\
hpovsam\
ProductCode={DB3CBE6B-0715-4214-900F-D6AAA7016C98}
ProductVersion=03.00.0307.0002
4. Open the file, solid.ini, located in the managementserver\db installation directory.
For example:
C:\program files\Hewlett-Packard\sanmgr\managementserver\db\solid.ini