HP (Hewlett-Packard) 3400CL-24G Switch User Manual


 
6
Software Management
Install Recommendations for I.08.12 Boot ROM Update
Install Recommendations for I.08.12 Boot ROM Update
When installing the M.10.17 software to load the I.08.12 ROM version, ProCurve recommends that
you use the “fastboot” feature and the “reload” command after updating to M.10.17, as shown below.
ProCurve3400cl#config
ProCurve3400cl(config)# fastboot
ProCurve3400cl(config)# copy tftp flash <ip address of tftp server> M_10_17.swi
The Primary OS Image will be deleted, continue [y/n]? y Validating and Writing System
Software to FLASH...
ProCurve3400cl(config)# reload
Device will be rebooted, do you want to continue [y/n]? y
Rebooting the System
Then reconnect and run the show flash command:
ProCurve3400cl# show flas
Image Size(Bytes) Date Version
----- ---------- -------- -------
Primary Image : 3576793 09/26/06 M.10.17
Secondary Image : 3506627 05/26/06 M.10.07
Boot Rom Version: I.08.12
Current Boot : Primary
Please also refer to “Known Issues” on page 24 for additional information regarding updating to the
M.10.20 software release.