Software Fixes in Release M.08.51 - M.10.72
Release M.10.48
The switch does not send an appropriate exit status message to the client. This corrects
the symptom that occurs in some applications, which reports a message similar to:
Fatal error: Server unexpectedly closed connection.
The SSH client application does not get a command prompt (or equivalent) back from
the switch until the OS is verified and burned to flash.
•The show flash command incorrectly shows an OS image present in flash before the OS
is completely copied to flash.
Mirroring (PR_1000460844) — When multiple VLANs are configured on the same port
and VLAN monitoring is enabled, packets to other VLANs are mirrored.
Release M.10.48
Problems Resolved in Release M.10.48 (Not a Public Release)
Daylight Savings (PR_1000467724) — DST is outdated for the Western European time
zone. This change corrects the schedule for Western Europe time zone: DST to start the last
Sunday in March and DST to end the last Sunday in October.
SNMP (PR_1000715545) — Buffered log messages (those log messages occurring in the
switch's event log prior to an IP address being enabled) are not filtered properly at boot up
when the switch is configured to send those log messages as traps. For example, non-critical
log entries may get sent to trap destinations configured to receive only critical events.
Crash (PR_1000464345) — The characters "IP(" when present as part of a port name may
cause config corruption when the switch is restarted.
SFTP/SCP (PR_1000428974) — SFTP or SCP transfer of the configuration files fails to
complete.
Release M.10.49
Problems Resolved in Release M.10.49 (Not a Public Release)
Port Security (PR_1000755715) — Port Security Mac Lockdown send-disable allows a
few frames through.
Running/Startup Config (1000750637) — SNMPv3 users are not correctly reflected in
startup config. The running-config and startup-config are not in sync, after a fresh configu-
ration load and reboot.
Sflow (PR_1000749192) — Trunked ports show the following sFlow sampling inaccura-
cies: