HP (Hewlett-Packard) 3400CL-24G Switch User Manual


 
20
Clarifications and Updates
Operating Notes for Jumbo Traffic-Handling
Clarifications and Updates
Operating Notes for Jumbo Traffic-Handling
In the Management and Configuration Guide, (Oct., 2005 version) on page 14-33 ( page 347 of the .pdf
file) where it states:
When a port is not a member of any jumbo-enabled VLAN, it drops all jumbo traffic. If the port
is receiving “excessive” inbound jumbo traffic, the port generates an Event Log message to notify
you of this condition. This same condition generates a Fault-Finder message in the Alert log of
the switch’s web browswer interface, and also increments the switch’s “Giant Rx” counter.
Note that it is the “Total Rx Errors” counter that is incremented, not the “Giant Rx” counter. On the
3400cl and 6400cl series switches, when the switch applies the jumbo MTU to a VLAN, all frames
with jumbo MTU sizes (1523 to 9220 bytes) are incremented to “Total Rx Errors”.
Non-Genuine Mini-GBIC Detection and Protection Initiative
Non-genuine ProCurve Transceivers and Mini-GBICs have been offered for sale in the marketplace.
To protect customer networks from these unsupported products, ProCurve switch software includes
the capability to detect and disable non-genuine transceivers and mini-GBICs discovered in Series
3400cl Switch ports. When a non-genuine device is discovered, the switch disables the port and
generates an error message in the Event Log.
Publication Updates
Table 1 lists updates to the manual set dated January, 2005.
Table 1. Publication Updates for Manual Set Dated January, 2005
Management and Configuration Guide
for the 3400cl, 5300xl, & 6400cl
Switches, p/n 5990-6050, January 2005
Edition
Update
Chapter 14: “Configuring for Network
Management Applications”
Pages 14-44 and 14-49
The
show lldp info stats is an invalid command.
The correct syntax is: show lldp stats.