HP (Hewlett-Packard) 960i Computer Drive User Manual


 
44
Ready is FLASHING fast.
The drive is
downloading firmware.
None.
Do not reset or power cycle the drive.
Ready is OFF, others are
ON.
Firmware is being
reprogrammed.
None.
Do not reset or power cycle the drive.
Clean is FLASHING.
The drive requires
cleaning.
Load the Ultrium cleaning cartridge. See page 28 for
supported cartridges and instructions.
If the Clean LED is still flashing when you load a new
or known data cartridge after cleaning, call for
service.
Ready is FLASHING and
Clean is ON.
Cleaning is in progress.
None. The cleaning cartridge will eject on
completion.
The cleaning cycle can take up to 5 minutes to
complete.
Tape Error is FLASHING.
The drive believes the
current tape or the tape
just ejected is faulty.
Unload the tape cartridge. Make sure that you are
using the correct format cartridge; an Ultrium data
cartridge or Ultrium Universal cleaning cartridge.
(See page 28.)
Reload the cartridge. If the Tape Error LED still flashes
or starts flashing during the next backup, load a new
or known, good cartridge.
If the Tape Error LED is now off, discard the 'suspect'
tape cartridge. If it is still on, call for service.
The tape is ejected
immediately and Tape
Error is FLASHING, or
Drive Error FLASHES on
unloading tape.
The tape cartridge
memory (CM) may be
faulty.
Write-protect the cartridge by sliding the red switch
on the tape cartridge. The tape can be loaded and
the data read. Once the data is recovered, the
cartridge must be discarded.
Drive Error FLASHING.
The drive mechanism
has detected an error.
Load a new cartridge. If the error persists, power
cycle or reset the drive.
If the Drive Error LED remains on, call for service.
LED
Sequence
Cause Action required
or
ult960_master_internal.fm Page 44 Tuesday, September 21, 2004 4:13 PM