HP (Hewlett-Packard) B6941-90001 Server User Manual


 
Chapter 10 381
Tuning, Troubleshooting, Security, and Maintenance
Troubleshooting: Tracing
See Table 10-1 “Functional Tracing Areas” for a list of all available
areas. MSG and ACTN are enabled by default.
NOTE Spaces are not allowed between entries in the lists for
OPC_TRACE_AREA and OPC_TRC_PROCS.
3. To receive verbose trace information output, add:
OPC_TRACE_TRUNC FALSE
OPC_TRACE_TRUNC TRUE is enabled by default.
4. Inform the running ITO software of the configuration change as user
root:
management server processes:
/opt/OV/bin/OpC/opcsv -trace
or restart the management server processes:
/opt/OV/bin/OpC/opcsv -start
managed node processes:
/opt/OV/bin/OpC/opcagt -trace
or re-start the managed node processes:
/opt/OV/bin/OpC/opcagt -start
The following example shows an opcsvinfo file with tracing activated:
#################################################################
# File: opcsvinfo
# Description: OpC Installation Information of Management Server
# Package: HP OpenView IT/Operations
# Status:
#
# (c) Copyright Hewlett-Packard Co. 1998
#
#################################################################
OPC_INSTALLED_VERSION A.05.00
OPC_MGMT_SERVER arthur.ashe.hp.com
OPC_INSTALLATION_TIME 23/01/98 15:06:18
OPC_TRACE TRUE
OPC_TRACE_AREA INT,ACTN
OPC_TRACE_TRUNC FALSE
#################################################################
# end of opcsvinfo
#################################################################