HP (Hewlett-Packard) D2D2503 Computer Drive User Manual


 
5. Install the SAAP license.
a. Reboot the system.
b. During the POST screen, when advised, hit any key to see further messages.
c. Enter the Smart Array POST ORCA utility by pressing [F8] when details for the P411 card
are displayed during the POST messages.
d. Select the Manage Licenses option in the Smart Array menu, and then select Install Licenses.
e. Enter the licence key previously noted.
P812 controller failure (HP D2D4324)
IMPORTANT: When replacing the P812 controller be sure to always replace cards into the same
slot from which they were removed. See also the rear view drawings in Chapter 1. The FBWC is
an integral part of the card.
1. Power off the HP D2D Backup System. Remove the cover from the HP D2D, as described in
the appropriate HP ProLiant Maintenance and Service guide, and locate the P812 controllers
in PCI-e slots 4, 5 and 6.
NOTE: The LEDs on the P812 controller card provide diagnostic information when the unit
is powered on. For a detailed description of these LEDs, refer to the “HP Smart Arrays for HP
ProLiant Servers user guide”.
2. Unclip the blue PCIe card retaining latch and remove the PCIe card.
3. Install the new P812 card and check that it is seated properly. Close the blue PCIe card
retaining latch.
4. Replace the cover, as described in the appropriate HP ProLiant Maintenance and Service
guide, and power on the HP D2D Backup System.
HP SAS expander card (HP D2D4324 and D2D4312)
If no disks are showing on the Storage-Shelves page of the D2D Web Management Interface, there
may be a problem with the HP SAS expander card.
The part number for a replacement card is: 468405–001. It must be installed in PCI-e slot 1.
Mini-SAS cables (part numbers 493228–005 and 493228–006) connect the expander card to
the hard disk drive backplane, as described in the following table. SAS cables are also connected
from the motherboard to the SAS expander card
NOTE: Tuck the mini-SAS cables to be routed to the backplane into the side of the chassis. Loop
the SAS cables to connect to the motherboard in the void.
Table 7 Cabling to HP SAS expander card (HP D2D4312)
ToFrom.Connect
Bottom right HDD backplane
connector
Port 2C on SAS expander card493228–006 mini-SAS cable1
Top right HDD backplane connectorPort 3C on SAS expander card493228–006 mini-SAS cable2
Bottom left HDD backplane
connector
Port 4C on SAS expander card493228–005 mini-SAS cable3
Top left HDD backplane connectorPort 5C on SAS expander card493228–005 mini-SAS cable4
Port 8C on the SAS expander cardConnector A (left) on the
motherboard
SAS cable5
Port 9C on the SAS expander cardConnector B (right) on the
motherboard
SAS cable6
32 The HP SmartArray P410i and P812/P411 RAID controllers and HP SAS expander card (HP D2D4324 and 4312)