HP (Hewlett-Packard) HP c-Class BladeSystem Switch User Manual


 
B Electrostatic discharge
This appendix provides the following information:
How to prevent electrostatic discharge
Grounding methods
How to prevent electrostatic discharge
To prevent damage to the system, you must follow certain precautions when setting up
the system or handling parts. A discharge of static electricity from a nger or other
conductor may damage system boards or other static-sensitive devices. This type of
damage may reduce the life expectancy of the device.
To prevent electrostatic damage, observe the following precautions:
Avoid hand co
ntact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free
workstations.
Place parts
on a grounded sur face before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always make sure you are properly grounded when touching a static-sensitive
component
or assembly.
Grounding methods
There are several methods for grounding. Use one or more of the following methods
when handling or installing electrostatic-sensitive parts:
Use a wrist strap connected by a ground cord to a grounded workstation or
chassis. Wrist straps are exible straps with a minimum of 1 megohm ± 10
percent resistance in the ground cords. To provide proper ground, wear the
strap snug against the skin.
Use heel straps, toe straps, or boot straps at standing workstations. Wear the
straps on both feet when standing on conductive oors or static-dissipating oor
mats.
Use conductive eld service tools.
Use a portable eld service kit with a folding static-dissipating work m at.
Brocade 4Gb SAN Switch for HP c-Class BladeSystem