HP (Hewlett-Packard) HP c-Class BladeSystem Switch User Manual


 
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions
beyond those
for which it was tested. The ranges specied in Table 17 list the acceptable
environment
for both operating and non-operating conditions.
Table 17 Environmental requirements
Condition Acceptable
range during operation
Acceptable
range during
non-operation
Ambient
temperature
104°F/40 °C
at sea level, derated 1 C
per 1000 ft
above sea level
-40°C to 70°
Cwithmaximumrateof
change of 2
0C/hr
Humidity 5% to 90% relative humidity,
non-condensing
50%to80%relativehumidity,
non-condensing
Altitude
0to10,000ft(3km)abovesealevel 0to40,000ft(12km)abovesealevel
Shock 40 G, 2mS d
uration
140 G, 2mS,
Vibration
0.5G,10500Hz 2.0G,5500Hz
Airow 4 7 cubic ft/minute
None required
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not tcorrectly
and may void your warranty. See Optional hardware kits for a list of supported SFPs.
For a com
plete list of supported devices, refer to the latest version of the HP
StorageWorks SAN design reference guide: h
ttp://h18000.w ww1.hp.com/products/
storageworks/san/documentation.html.
Supported HBAs
For a list of HBAs that have been tested a nd are known to work with the SAN switches,
refer to the latest version of the HP StorageWorks SAN design reference guide:
h
ttp://h18000.w ww1.hp.com/products/storageworks/san/documentation.html.
76
SAN Switch technical specications