Honeywell 2020 Barcode Reader User Manual


 
B - 3
Scan the Relink Time-Out bar code, then scan the number of seconds for the
setting (from 1-100) from the inside back cover. Scan Save to save the setting.
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values:
When the image scanner goes out of range, the image scanner repeatedly
attempts to connect to base unit. Each attempt consists of approximately 5
seconds of active time followed by 3 seconds of idle time. After one hour, the
image scanner powers off and batch mode data is lost.
Maximum Link Attempts set to 15
Other values at default setting:
When the image scanner goes out of range, 15 attempts are made to link to
the base unit. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2
minutes, the image scanner stops trying to connect to the base unit, but retains
any bar codes that may have been saved in batch mode. After one hour, the
image scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default setting:
When the image scanner goes out of range, no action is taken to re-link. When
the trigger is pulled, 15 attempts are made to link to the base unit. Each
attempt consists of approximately 5 seconds of active time followed by 3
seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the
image scanner stops trying to connect to the base unit, but retains any bar
codes that may have been saved in batch mode. After one hour, the image
scanner powers off and batch mode data is lost. Refer to (see Auto Reconnect
Mode on page B-1), to review other events that can start the re-link process.
Relink Time-Out