and xxyy .. zz is the list of characters to be suppressed. (xx stands for the
hex value for an ASCII code, see
ASCII Conversion Chart (Code Page
1252) on page A-3.)
FC Disables suppress filter and clear all suppressed characters.
Syntax = FC.
E4 Replaces up to 15 characters in the data string with user-specified charac-
ters. Replacement continues until the E5 command is encountered.
Syn-
tax = E4nnxx
1
xx
2
yy
1
yy
2
...zz
1
zz
2
where nn is the total count of both
characters to be replaced plus replacement characters; xx
1
defines charac-
ters to be replaced and xx
2
defines replacement characters, continuing
through zz
1
and zz
2
.
E5 Terminates character replacement.
Syntax = E5.
FE Compare character in current cursor position to the character “xx.” If char-
acters are equal, increment cursor. If characters are not equal, no format
match.
Syntax = FExx
(xx stands for the hex value for an ASCII code, see
ASCII Conversion Chart (Code Page 1252) on page A-3.)
EC Check to make sure there is an ASCII number at the current cursor posi-
tion. If character is not numeric, format is aborted.
Syntax = EC
.
ED Check to make sure there is a non-numeric ASCII character at the current
cursor position. If character is numeric, format is aborted.
Syntax = ED
.
Data Format Editor
Enter Data Format
* Default Data Format
Clear One Data Format
Save
Discard
Clear All Data Formats