Honeywell 3800r Scanner User Manual


 
6 - 3
Secondary Laser Emulation
Note: Models 3800iSR000E and 3800rSR000E require 35122063.bin software.
Contact Technical Support to obtain this software (see
Technical
Assistance on page 14-1).
Use this selection when connecting to a secondary terminal with integral decod-
ing. This also sets the transmission rate to 36 scans per second, the polarity to
white high, and deletes all prefixes and suffixes.
When you scan the following bar code, the imager sends the raw data edges to
the host for host decoding. This also sets the transmission rate to 36 scans per
second and the polarity to white high.
When you scan the following bar code, the scanner decodes and re-encodes
the data and sends the data to the host as Code 39.
Laser Emulation Transmission Rate
The transmission rate is limited by the terminal’s ability to receive data without
dropping characters.
Default = 36 scans/second.
* Laser Emulation
Same Code Output
Laser Emulation
Raw Output
Laser Emulation
Code 39 Output
* 36
100