Honeywell NETAXS-123 Network Hardware User Manual


 
Installing the NetAXS-123 Panels
Basic Standalone Operation
NetAXS-123 Access Control Unit Installation Guide, Document 800-05779, Revision A 63
6.0 Basic Standalone Operation
6.1 Card Read / Door Lock Operation
1. Present a card to a reader.
2. The reader sends the card number to a reader input on the panel.
3. The panel searches its database and:
If it is a valid card, then energize the door relay associated with the particular reader
input. The card is valid when it is in the card database on the panel and the current time
and date conforms to the time zone associated with the card.
If it is not a valid card, the door relay remains locked.
6.2 Door Egress / Door Lock / Door Status Operation
1. Activate the door egress input.
2. The panel energizes the door relay associated with the particular door egress input for a default
time of 10 seconds.
3. If the door status goes from close to open to close again during the 10 second door open period,
the door relay will be immediately de-energized.