7-12 CHAPTER 7: TROUBLESHOOTING
Shared RAM Write/Read Test Failure
Make sure the shared RAM address does not conflict with the
adapter ROM or another device.
Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.
Timer Test Failure
The adapter’s timer is incorrect or the PC timer is malfunctioning.
Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.
Open Adapter for Ring Operation Test Failure
Make sure a lobe cable is properly connected to the adapter
and that the other end of the cable is connected to a DAU,
MAU, or CAU.
Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.
Ring Operations Test Failure
Run the Group 2 Adapter Wrap Test. If the test is successful,
the error condition may be related to the ring itself.
Make sure a lobe cable is properly connected to a MAU.
Make sure the selected adapter speed matches the ring
speed.
Try another shared RAM address and size.
Retry the operation after delaying at least 30 seconds.