DOES THE HARDWARE CONFIGURATION REPORT CORRECTLY
IDENTIFY THE DEVICES INSTALLED IN THE SYSTEM UNIT?
Yes No
007
– The System Configuration Report shows only those devices
supported by the Diagnostics and Utilities CD and only
factory-installed devices for the model you are servicing.
– If a device is missing from the list and is not factory installed, refer
to the service manual provided for that device. (Refer to the
Appendix B, “Model/Monitor Configurations and FRU Part Numbers”
on page B-1 to determine the factory-installed devices in the model
you are servicing.)
– If a factory-installed drive device or adapter card is not listed in the
System Configuration Report, return to “Start” on page 2-2 and then
go to “Factory-Installed Drive Devices” on page 2-47.
008
– Select Diagnostics Menu from the Main Menu.
– Select Easy Test Diagnostics from the Diagnostics Menu.
DOES THE EASY TEST FINISH WITHOUT ERROR CODES?
Yes No
009
– If the last test stops and you cannot continue, first make sure all
switches, power connectors, cables, and jumpers are set correctly
and show the correct voltages and continuity.
– Make note of any messages, error codes, beeps, or new symptoms.
Go to “Index of Symptoms, Messages, Error Codes, or Beeps” on
page 2-9.
010
– The Easy Test Diagnostics did not detect a failure. If the system still
display a failure:
Check all adapter card jumper settings.
Check all adapter card switch settings.
Check all adapter card cables and connectors for proper installation.
Make sure all of the above are set correctly and show the correct
voltages and continuity. Replace any defective cables or adapter
cards. See “Power Supply” on page 2-34, “System Board
2-44