IBM 2274 Personal Computer User Manual


 
56 IBM Desktop System HMM
NOTE: The CD-ROM drive that comes with syste
unit should be configured as IDE Secondary
Channel Master device.
Check all power supply voltages, switch, and
jumper settings before you replace the system
board. (See System Board Jumpers and
Connectors on page 109)
Check the power supply voltages if you have a
system no-power condition. See Power Supply
Connectors and Voltages on page 111.
Check the hard disk and CD-ROM drives jumper
settings. See 3.5-In. Hard Disk Drive Jumper
Settings on page 117. Check the voltages of all
disk drive power connectors. See Power Supply
Connectors and Voltages on page 111.
Correct the parameter settings under Disk Drives
in the Configuration/Setup Utility. See Hard Disk
Drive on page 4.
- In the Configuration/Setup Utility, check that the
correct drive size is set for the flagged drive
shown in the System Information. See Viewing
System Information, and Product Data on page
17.
Enter Configuration/Setup Utility and load default
settings.
If the problem remains, check the continuity on the
drive and the cable and replace it if necessary. If
that does not fix the problem, replace the syste
board.
End.
005 -
Select Diagnostics from the PC-Doctor diagnostics
program main menu. Select and execute Floppy
Disk Test if you want to test diskette drive. Select
and execute Hard Disk Test if you want to test hard
disk drive.
Select Interactive Tests from the PC-Doctor
diagnostics program main menu, then select and
execute CD-ROM/DVD Test if you want to test CD-
ROM drive.