Message Failure Found Recommended Actions
2xx-1y A memory error was detected in
SIMM socket Y.
Replace the SIMM in the socket
identified by the last digit of the
error code.
Re-run the test.
If the same error code occurs
again, replace the system board.
2xx-2y A memory error was detected in
DIMM/RIMM socket Y
Replace the DIMM/RIMM in the
socket identified by the last digit
of the error code.
Re-run the test.
If the same error code occurs
again, replace the system board
or where memory is on the
processor card, replace the
processor card.
Corrupt BIOS Information in BIOS is not as
expected.
Not able to find expected DMI
information from BIOS.
Memory controller chipset
vendor ID does not match
expected value.
Reflash the BIOS.
Perform boot block recovery.
Replace the system board.